The connection of solenoid valve product is relatively simple, the power line of general solenoid valve has ground wire, positive pole and negative pole, if it is communication electricity, the positive and negative pole of wiring can not be considered, if it is direct current, it is necessary to pay attention to positive and negative pole, and pay attention to the same voltage. The detailed wiring diagram of solenoid valve is as follows:

Precautions for solenoid valve installation

1. First, check whether the Ross solenoid valve is consistent with the selection parameters, such as power supply voltage, medium pressure, differential pressure, etc., especially the power supply. If it is wrong, the coil will be burned out. The power supply voltage should meet the voltage fluctuation range of rated voltage: communication + 10% ~ - 15%, DC + 10% ~ - 10%. Usually, the coil assembly should not be disassembled.

2. Before receiving, the pipeline should be flushed, and the metal powder and sealing material residues, rust and scale in the pipeline should be removed. The medium in the filter screen should be clean, if there is dirt in the filter, the filter should be clean.

3. In general, the solenoid coil components of solenoid valve should be vertical upward. If the vertical device is horizontal on the ground, if it is necessary to follow the side device due to space limitation or working condition requirements, it should be put forward in the selection and ordering. Otherwise, the solenoid valve may not work normally.

4. Manual cut-off valve shall be added before and after the solenoid valve, and bypass shall be set together to facilitate the protection of solenoid valve in case of fault.

5. The solenoid valve is generally directional and can not be installed reversely. It is usually used on the valve body to point out the medium flow direction, and the device should follow the direction device indicated by. However, it can be installed reversely in vacuum pipeline or special circumstances.

6. If the medium will water hammer phenomenon, then it should choose the solenoid valve with water hammer function or adopt corresponding preventive measures.

7. Try not to let the solenoid valve in the power on state for a long time, so as to simply reduce the service life of the coil or even burn out the coil, that is, the normally open and normally closed solenoid valves cannot be used interchangeably.

8. The steam solenoid valve inlet side should be equipped with a drain valve, where the receiving should be tilted.